Hostname: page-component-7c8c6479df-hgkh8 Total loading time: 0 Render date: 2024-03-28T08:11:11.229Z Has data issue: false hasContentIssue false

Retinal image quality in the rodent eye

Published online by Cambridge University Press:  01 April 1998

PABLO ARTAL
Affiliation:
Laboratorio de Optica, Departamento de Física, Universidad de Murcia, Murcia, Spain
PILAR HERREROS de TEJADA
Affiliation:
Departamento de Psicobiologia, Universidad Complutense de Madrid, Madrid, Spain
CARMEN MUÑOZ TEDÓ
Affiliation:
Departamento de Psicobiologia, Universidad Complutense de Madrid, Madrid, Spain
DANIEL G. GREEN
Affiliation:
Department of Ophthalmology, University of Michigan, Ann Arbor

Abstract

Many rodents do not see well. For a target to be resolved by a rat or a mouse, it must subtend a visual angle of a degree or more. It is commonly assumed that this poor spatial resolving capacity is due to neural rather than optical limitations, but the quality of the retinal image has not been well characterized in these animals. We have modified a double-pass apparatus, initially designed for the human eye, so it could be used with rodents to measure the modulation transfer function (MTF) of the eye's optics. That is, the double-pass retinal image of a monochromatic (λ = 632.8 nm) point source was digitized with a CCD camera. From these double-pass measurements, the single-pass MTF was computed under a variety of conditions of focus and with different pupil sizes. Even with the eye in best focus, the image quality in both rats and mice is exceedingly poor. With a 1-mm pupil, for example, the MTF in the rat had an upper limit of about 2.5 cycles/deg, rather than the 28 cycles/deg one would obtain if the eye were a diffraction-limited system. These images are about 10 times worse than the comparable retinal images in the human eye. Using our measurements of the optics and the published behavioral and electrophysiological contrast sensitivity functions (CSFs) of rats, we have calculated the CSF that the rat would have if it had perfect rather than poor optics. We find, interestingly, that diffraction-limited optics would produce only slight improvement overall. That is, in spite of retinal images which are of very low quality, the upper limit of visual resolution in rodents is neurally determined. Rats and mice seem to have eyes in which the optics and retina/brain are well matched.

Type
Research Article
Copyright
1998 Cambridge University Press

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)