Hostname: page-component-76fb5796d-5g6vh Total loading time: 0 Render date: 2024-04-26T15:49:08.332Z Has data issue: false hasContentIssue false

Graphene Grown on Ion-Implanted 4H-SiC and an Effect of Pre-Plasma Treatment

Published online by Cambridge University Press:  08 July 2014

Toru Sugimachi
Affiliation:
Department of EEE and Research Center for Micro-Nano Technology, Hosei University, Tokyo, Japan.
Yusuke Shiina
Affiliation:
Department of EEE and Research Center for Micro-Nano Technology, Hosei University, Tokyo, Japan.
Daiki Aoyagi
Affiliation:
Department of EEE and Research Center for Micro-Nano Technology, Hosei University, Tokyo, Japan.
Tomoaki Nishimura
Affiliation:
Research Center of Ion Beam Technology, Hosei University, Tokyo, Japan.
Tohru Nakamura
Affiliation:
Department of EEE and Research Center for Micro-Nano Technology, Hosei University, Tokyo, Japan.
Get access

Abstract

4H-SiC substrates were annealed at 1500 °C for 30 min in 0.01 MPa Ar gas flow to make a graphene film. To clarify the effect of Al ion implantation and pre-plasma treatment, the graphene was fabricated on four different kinds of SiC substrates: without plasma treatment, with plasma treatment, Al ion-implanted without plasma treatment and Al ion-implanted with plasma treatment. The graphene films were analyzed by AFM and Raman spectroscopy. The Al ion implanted sample, which was then processed by CF4 plasma, showed small surface roughness of 3.49 nm (RMS), while the sample without CF4 plasma treatment showed large surface roughness of 8.41nm. Similar results were also observed for SiC samples without Al ion implantation. In Raman spectra, strong D-band, G-band and 2D-band signals were detected on both ion-implanted samples after annealing at 1500 °C, but weak D-band were observed on both samples without Al ion implantation. Raman mapping (2D-FWHM) showed that the graphene on ion-implanted SiC treated with CF4 plasma was more homogeneous than the one without CF4 plasma treatment. Hall measurements for SiC without Al ion implantation showed that graphene on SiC treated with CF4 plasma has higher mobility (389 cm2/Vs) than that without plasma treatment (136 cm2/Vs). Additionally, p-type graphene can be fabricated on Al ion-implanted SiC by CF4 plasma treatment.

Type
Articles
Copyright
Copyright © Materials Research Society 2014 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

Morozov, S.V., Novoselov, K.S., Katsnelson, M.I., Schedin, F., Elias, D.C., Jaszczak, J.A. and Geim, A.K., Phys. Rev. Lett. 100, 016602 (2008).CrossRefGoogle Scholar
Ohta, T., Bostwick, A., Seyller, T., Horn, K. and Rotenberg, E., Science 313, 951 (2006).CrossRefGoogle Scholar
Strudwick, A. J. and Marrows, C. H., J. Mater. Res. 28, 1 (2013).CrossRefGoogle Scholar
Riedl, C., Coletti, C., Iwasaki, T., Zakharov, A. A., and Starke, U., Phys. Rev. Lett. 103, 246804 (2009).CrossRefGoogle Scholar
Sugimoto, T., Satoh, M. and Nakamura, T., in Proceedings of the 28th Symposium on Materials Science and Engineering, Tokyo, Japan, 4 December 2009 (Research Center of Ion Beam Technology, Hosei Univ.), p. 93.Google Scholar