The potential and limitations of neutrons, electrons and X-rays for atomic resolution microscopy of unstained biological molecules

Published online by Cambridge University Press:  17 March 2009

Richard Henderson
Affiliation:
MRC Laboratory of Molecular Biology, Hills Road, Cambridge CB2 2QH, UK

Summary

Radiation damage is the main problem which prevents the determination of the structure of a single biological macromolecule at atomic resolution using any kind of microscopy. This is true whether neutrons, electrons or X-rays are used as the illumination. For neutrons, the cross-section for nuclear capture and the associatedenergy deposition and radiation damage could be reduced by using samples that are fully deuterated and 15N-labelled and by using fast neutrons, but single molecule biological microscopy is still not feasible. For naturally occurring biological material, electrons at present provide the most information for a given amount of radiation damage. Using phase contrast electron microscopy on biological molecules and macromolecular assemblies of ˜ 105 molecular weight and above, there is in theory enough information present in the image to allow determination of the position and orientation of individual particles: the application of averaging methods can then be used to provide an atomic resolution structure. The images of approximately 10000 particles are required. Below 105 molecular weight, some kind of crystal or other geometrically ordered aggregate is necessary to provide a sufficiently high combined molecular weight to allow for the alignment. In practice, the present quality of the best images still falls short of that attainable in theory and this means that a greater number of particles must be averaged and that the molecular weight limitation is somewhat larger than the predicted limit. For X-rays, the amount of damage per useful elastic scattering event is several hundred times greater than for electrons at all wavelengths and energies and therefore the requirements on specimen size and number of particles are correspondingly larger. Because of the lack of sufficiently bright neutron sources in the foreseeable future, electron microscopy in practice provides the greatest potential for immediate progress.

Type
Research Article
Copyright
Copyright © Cambridge University Press 1995

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Abramowitz, M. & Stegun, I. A. (1965). Handbook of Mathematical Functions with Formulas, Graphs and Mathematical Tables. New York: Dover Publications.Google Scholar
Adrian, M., Heggeler-Bordier, B. T., Wahli, W., Stasiak, A. Z., Stasiak, A. & Dubochet, J. (1990). Direct visualisation of supercoiled DNA molecules in solution. EMBO J. 9, 45514554.Google Scholar
Arndt, U. (1984). Optimum X-ray wavelength for protein crystallography. J. Appl. Cryst. 17, 118119.Google Scholar
Baker, T. S., Newcomb, W. W., Olson, N. H., Cowsert, L. M., Olson, C. & Brown, J. D. C. (1991). Structures of bovine and human papillomaviruses – analysis by cryoelectron microscopy and 3-dimensional image-reconstruction. Biophys. J. 60, 14451456.Google Scholar
Breedlove, J. R. & Trammell, G. T. (1970). Molecular microscopy: fundamental limitations. Science, 170, 13101313.Google Scholar
Cowley, J. M. (1975). Diffraction Physics Amsterdam: North-Holland.Google Scholar
Darwin, C. G. (1914). The theory of X-ray reflexion. Phil. Mag. 27, 315333.Google Scholar
De Rosier, D. J. & Klug, A. (1968). Reconstruction of three-dimensional structures from electron micrographs. Nature 217, 130134.Google Scholar
Erickson, H. & Klug, A. (1971). Measurement and compensation of defocusing and aberrations by Fourier processing of electron micrographs. Phil. Trans. Roy. Soc. Lond., B 261, 105118.Google Scholar
Gabor, D. (1948). A new microscopic principle. Nature, 161, 777778.Google Scholar
Glaeser, R. M. & Ceska, T. A. (1989). High-voltage electron diffraction from bacteriorhodopsin (purple membrane) is measurably dynamical. Acta Cryst. A45, 620628.Google Scholar
Gonzalez, A., Thompson, A. W. & NAVE, C. (1992). Cryo-protection of protein crystals in intense X-ray beams. Rev. Sci. Instrum. 63, 11771180.Google Scholar
Henderson, R. (1990). Cryo-protection of protein crystals against radiation damage in electron and X-ray diffraction. Proc. Roy. Soc. B 241, 68.Google Scholar
Henderson, R. (1992). Image contrast in high resolution electron microscopy of biological macromolecules: TMC in ice. Ultramicroscopy 46, 118.Google Scholar
Henderson, R. & Glaeser, R. M. (1985). Quantitative analysis of image contrast in electron micrographs of beam-sensitive crystals. Ultramicroscopy 16, 139150.Google Scholar
Henderson, R., Baldwin, J. M., Ceska, T. A., Beckmann, E., Zemlin, F. & Downing, K. (1990). A model for the structure of bacteriorhodopsin based on high resolution electron cryomicroscopy. J. Mol. Biol. 213, 899929.Google Scholar
Hoppe, W. (1983). Electron diffraction with the transmission electron microscope as a phase-determining diffractometer - from spatial frequency filtering to the three-dimensional structure analysis of ribosomes. Angew. Chem. Int. Ed. Engl. 22, 456485.Google Scholar
Hubbell, J. H., Gimm, H. A. & Øverbø, I. (1980). Pair, triplet and total atomic cross sections (and mass attenuation coefficients) for 1Mev-100Gev photons in elements Z = 1 to 100. J. Phys. Chem. Ref. Data 9, 10231147.Google Scholar
Jacobsen, C., Williams, S., Anderson, E., Browne, M. T., Buckley, C. J., Kern, D., Kirz, J., Rivers, M. & Zhang, X. (1991). Diffraction-limited imaging in a scanning transmission X-ray microscope. Optics Commun. 86, 351364.Google Scholar
Jap, B. K., Walian, P. J. & Gehring, K. (1991). Structural architecture of an outermembrane channel as determined by electron crystallography. Nature 350, 167170.Google Scholar
Jeng, T.-W., Crowther, R. A., Stubbs, G. & Chiu, W. (1989). Visualisation of alphahelices in tobacco mosaic virus by cryo-electron microscopy. J. Mol. Biol. 205, 251257.Google Scholar
Kirz, J., Ade, H., Jacobsen, C., Ko, C.-H., Lindaas, S., McNulty, I., Sayre, D., Williams, S. & Zhang, X. (1992). Soft X-ray microscopy with coherent X-rays. Rev. Set. Instrum. 63, 557563.Google Scholar
Kühlbrandt, W. & Wang, D. N. (1991). Three-dimensional structure of plant lightharvesting complex determined by electron crystallography. Nature 350, 130134.Google Scholar
Kühlbrandt, W., Wang, D. N. & Fujiyoshi, Y. (1994). Atomic model of plant lightharvesting complex by electron crystallography. Nature 367, 614621.Google Scholar
Langmore, J. P. & Smith, M. F. (1992). Quantitative energy-filtered electron microscopy of biological molecules in ice. Ultra-microscopy 46, 349373.Google Scholar
Licht, H. (1991). Optimum focus for taking electron holograms. Ultramicroscopy 38, 1322.Google Scholar
Penczek, P., Radermacher, M. & Frank, J. (1992). Three-dimensional reconstruction of single particles embedded in ice. Ultramicroscopy 40, 3353.Google Scholar
Reimer, L. (1989). Transmission Electron Microscopy, 2nd ed. Berlin: Springer-Verlag.Google Scholar
Sayre, D. & Chapman, H. N. (1994). X-ray microscopy. Acta Cryst. A51 (In press).Google Scholar
Sayre, D., Kirz, J., Feder, R., Kim, D. M. & Spiller, E. (1977). Transmission microscopy of unmodified biological materials: comparative radiation dosages with electrons and ultrasoft X-ray photons. Ultramicroscopy 2, 337349.Google Scholar
Sears, V. F. (1992). Neutron scattering lengths and cross-sections. Neutron News 3(3), 2637.Google Scholar
Smith, M. F. & Langmore, J. P. (1992). Quantitation of molecular densities in cryoelectron microscopy: determination of the radial density distribution of tobacco mosaic virus. J. Mol. Biol. 226, 763774.Google Scholar
Spence, J. C. H. (1988). Experimental High-Resolution Electron Microscopy, 2nd ed., Oxford University Press.Google Scholar
Stewart, P. L., Burnett, R. M., Cyrklaff, M. & Fuller, S. D. (1991). Image reconstruction reveals the complex molecular organisation of Adenovirus. Cell 67, 145154.Google Scholar
Steyerl, A. (1989). Ultracold neutrons: production and experiments. Physica B, 156, 528533.Google Scholar
Steyerl, A., Drexel, W., Ebisawa, T., Gutsmiedle, E., Steinhauser, K.-A., Gahler, R., Mampe, W. & Ageron, P. (1988). Neutron microscopy. Rev. Phys. Appl. 23, 171180.Google Scholar
Thon, F. (1966). Zur Defokussierungsabhängigkeit des Phasenkontrastes bei der elektronenmikroskopischen Abbildung. Z. Naturforsh. 219, 476478.Google Scholar
Tonomura, A. (1992). Electron-holographic interference microscopy. Adv. Physics 41, 50103.Google Scholar
Toyoshima, C., Sasabe, H. & Stokes, D. L. (1993). Three-dimensional cryo-electron microscopy of the calcium ion pump in the sarcoplasmic reticulum membrane. Nature 362, 469471.Google Scholar
Toyoshima, C. & Unwin, N. (1988a). Contrast transfer for frozen-hydrated specimens: determination from pairs of defocused images. Ultramicroscopy 25, 279292.Google Scholar
Toyoshima, C. & Unwin, N. (1988b). Ion channel of acetyl-choline receptor reconstructed from images of postsynaptic membrane. Nature 336, 247250.Google Scholar
Zernike, F. (1955). How I discovered phase contrast. Science 121, 345349.Google Scholar